Vickers by Danfoss02-391226

02-391226

Vickers D08 Solenoid Valve
Item #101907446
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-391226
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Port T Pressure Rating 5000 psi
Electrical Connector Code T
Port Restrictor Plugs None
Rated Flow [Max] 185 gal/min
Crossover P Blocked, A or B to T
Port Restrictor Plug Code None
Pilot Pressure Code None
EN Code None
Indicator Lights Yes
Manual Override Plain Override
Valve Type Standard-Duty
Coil Type Code F
NFPA Size D08
Pilot Drain Code None
Coil Rating Code B
Pressure Port Check Valve Code None
Pilot/Drain External Pilot/Internal Drain
Solenoid Energization Code None
Function 3-Position Spring Centered
Electrical Options Code None
Mechanical Options Code None
Spool Control Modification Code None
Overrides Plain Override Solenoid Ends
Pilot Valve Type CETOP 3, Standard Performance
Model No. DG5V-8-S-6C-X-M-FTWL-B-10
Electrical Connection Wired Terminal Block
Seal Material Buna-N
Design No. 10
Pressure Port Check Valve Pressure N/A
Spool Code 6
Gauge Port SAE-4
Tank Port Rating 5000
Center Position P Blocked, A & B to T
Manual Override Option Code None
Reducer Module Code None
Mechanical Options None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options None
AC/DC AC
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Solenoid Double
Spool Indicator Switch Code None
Pilot Valve Type Code S
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code C
Response Type Code X
Reducer Module N/A
Gauge Ports Code None
Actuator Type Solenoid
Solenoid Indicator Lights Code L
Response Type Fast Response
Housing Code W
Pressure [Max] 5000 psi
Operation Pilot Operated
Weight 35.0 LB