Vickers D08 Solenoid Valve
Item #102098975
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344392
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Sudden, slam-type stalling should be avoided. Applications of this kind, which are beyond the expected normal performance of pneumatic power motors, will damage the power train due to the dynamic shock loads imposed.
Coil Rating Code H
Port Restrictor Plugs None
Electrical Options None
Fluid Cleanliness 19/17/14 micron
Mechanical Options None
Center Position P Blocked, A & B to T
Pilot Drain Code T
No. of Stages Two Stage
Watt Rating 30 W
Gauge Ports Code None
Spool Spring Arrangement Code C
Coil Type Code U
Manual Override Plain Override
Spool Indicator Switch Code None
Reducer Module No
Manual Override Option Code None
Compatible Fluids Petroleum Oil
Response Type Standard Response
Pressure [Max] 5000 psi
EN Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Indicator Lights No
Performance High Performance
NFPA Size D08
Spool Center Condition A Port and Double Offset sensing switch on B Port
Model No. DG5V-8-H-6C-T-M-U-H-10
Solenoid Double
Valve Type Standard-Duty
Surge Suppressor/Damper Code None
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Port Restrictor Plug Code None
Pilot/Drain External Pilot/Internal Drain
Body Material Gray Iron
AC/DC DC
Reducer Module Code None
Rated Flow [Max] 175 gal/min
Pressure Port Check Valve Pressure N/A
Electrical Options Code None
Pilot Valve Type CETOP 3, High Performance
Operation Pilot Operated
Pressure Port Check Valve Code None
Response Type Code None
Coil Type ISO 4400 (Din 43650) Connector
Tank Port Rating 5000
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Port T Pressure Rating 5000 psi
Electrical Connection No Connector
Mechanical Options Code None
Gauge Port SAE-4
Crossover P Blocked, A or B to T
Solenoid Energization Code None
Housing Code None
Pilot Valve Type Code H
Function 3-Position Spring Centered
Leakage Standard Performance
Electrical Connector Code None
Voltage & Frequency 24 VDC
Solenoid Indicator Lights Code None
Spool Control Modification Code None
Seal Material Buna-N
Design No. 10
Pilot Pressure Code None
Spool Code 6
Weight 35.0 LB