Vickers D08 Solenoid Valve
Item #101906035
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342445
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Indicator Lights No
Pilot Pressure Code None
Gauge Port SAE-4
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Spool Code 6
Gauge Ports Code None
Valve Type Standard-Duty
Pilot/Drain External Pilot/Internal Drain
EN Code None
Surge Suppressor/Damper Code None
Response Type Code None
Port Restrictor Plugs None
Center Position P Blocked, A & B to T
Manual Override Plain Override
Model No. DG5V-8-H-6C-3-T-M-FW-B-10
Electrical Options None
Housing Code W
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Pilot Valve Type CETOP 3, High Performance
Pilot Drain Code T
Port Restrictor Plug Code None
Reducer Module N/A
Coil Type Code F
Solenoid Energization Code None
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Design No. 10
Electrical Options Code None
AC/DC AC
Spool Indicator Switch Code None
Tank Port Rating 5000
NFPA Size D08
Function 3-Position Spring Centered
Crossover P Blocked, A or B to T
Pilot Valve Type Code H
Operation Pilot Operated
Rated Flow [Max] 185 gal/min
Spool Control Modification Code 3
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Standard Response
Electrical Connector Code None
Manual Override Option Code None
Mechanical Options Code None
Coil Rating Code B
Solenoid Double
Reducer Module Code None
Seal Material Buna-N
Electrical Connection No Connector
Spool Spring Arrangement Code C
Port T Pressure Rating 5000 psi
Weight 35.0 LB