Vickers by Danfoss02-337216

02-337216

Vickers D08 Solenoid Valve
Item #101975621
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337216
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Manual Override Plain Override
Pressure Port Check Valve Code None
Pilot Valve Type CETOP 3, Standard Performance
Port Restrictor Plugs None
Body Material Ductile Iron
EN Code None
Mechanical Options Code None
Coil Type Code F
Temperature Range [Max] 230 °F
Pressure [Max] 5000 psi
Electrical Options Code None
Valve Type Standard-Duty
Crossover All Ports Open
Compatible Fluids Petroleum Oil
Design No. 10
Reducer Module Code None
Manual Override Option Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Valve Type Code S
Spool Spring Arrangement Code C
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 5000 psi
Model No. DG5V-8-S-0C-2-E-M-FTWL-B-10
Overrides Plain Override Solenoid Ends
Actuation Identification Solenoid A, Solenoid B
Actuator Type Solenoid
Response Type Code None
Housing Code W
Spool Indicator Switch Code None
No. of Stages Two Stage
Temperature Range [Min] -40 °F
Electrical Connector Code T
Rated Flow [Max] 175 gal/min
Spool Control Modification Code 2
Mechanical Options Adjust Pilot Chokes on Both Ends
AC/DC AC
Pilot/Drain External Pilot/External Drain
Performance Standard Performance
Gauge Ports Code None
Pilot Drain Code None
Seal Material Buna-N
Tank Port Rating 5000
Operation Pilot Operated
Fluid Cleanliness 19/17/14 micron
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Reducer Module No
Mounting Subplate/Manifold Mount
Spool Code 0
Port Restrictor Plug Code None
Solenoid Energization Code None
Indicator Lights Yes
Gauge Port SAE-4
Center Position All Ports Open
Surge Suppressor/Damper Code None
Coil Rating Code B
Solenoid Double
Pilot Pressure Code E
Solenoid Indicator Lights Code L
Function 3-Position Spring Centered
NFPA Size D08
Response Type Standard Response
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options None
Electrical Connection Wired Terminal Block
Leakage Standard Performance
Weight 35.0 LB