Vickers D08 Solenoid Valve
Item #101975621
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337216
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Center Position All Ports Open
Surge Suppressor/Damper Code None
NFPA Size D08
Fluid Cleanliness 19/17/14 micron
Spool Control Modification Code 2
Voltage & Frequency 110/120 VAC - 50/60 Hz
Leakage Standard Performance
Housing Code W
Solenoid Energization Code None
Performance Standard Performance
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Drain Code None
Spool Code 0
Overrides Plain Override Solenoid Ends
Seal Material Buna-N
Body Material Ductile Iron
Solenoid Double
Temperature Range [Max] 230 °F
Rated Flow [Max] 175 gal/min
Operation Pilot Operated
Port Restrictor Plugs None
No. of Stages Two Stage
Pressure [Max] 5000 psi
Coil Rating Code B
Tank Port Rating 5000
Actuator Type Solenoid
Response Type Code None
Gauge Ports Code None
Electrical Connection Wired Terminal Block
Pressure Port Check Valve Code None
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Pilot Valve Type CETOP 3, Standard Performance
Mechanical Options Code None
AC/DC AC
Reducer Module Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Manual Override Plain Override
Manual Override Option Code None
Gauge Port SAE-4
Electrical Options Code None
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Pressure N/A
Compatible Fluids Petroleum Oil
Pilot/Drain External Pilot/External Drain
Function 3-Position Spring Centered
Spool Spring Arrangement Code C
Model No. DG5V-8-S-0C-2-E-M-FTWL-B-10
Temperature Range [Min] -40 °F
Indicator Lights Yes
Reducer Module No
Electrical Options None
Crossover All Ports Open
Spool Indicator Switch Code None
Coil Type Code F
Valve Type Standard-Duty
Response Type Standard Response
EN Code None
Pilot Valve Type Code S
Electrical Connector Code T
Solenoid Indicator Lights Code L
Actuation Identification Solenoid A, Solenoid B
Design No. 10
Pilot Pressure Code E
Weight 35.0 LB