- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Fluid Cleanliness | 19/17/14 micron |
| Response Type Code | None |
| Reducer Module Code | None |
| EN Code | None |
| Response Type | Standard Response |
| Housing Code | W |
| Pilot Drain Code | None |
| Electrical Connection | No Connector |
| Mechanical Options | None |
| Leakage | Standard Performance |
| Surge Suppressor/Damper Code | None |
| Mechanical Options Code | None |
| Port Restrictor Plugs | None |
| AC/DC | AC |
| Pilot Pressure Code | E |
| Pressure Port Check Valve Pressure | N/A |
| Temperature Range [Max] | 230 °F |
| Pressure [Max] | 5000 psi |
| Spool Code | 8 |
| Surge Suppressor/Damper | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Temperature Range [Min] | -40 °F |
| Performance | Standard Performance |
| Pressure Port Check Valve Code | None |
| Port Restrictor Plug Code | None |
| Seal Material | Buna-N |
| Reducer Module | No |
| Compatible Fluids | Petroleum Oil |
| Model No. | DG5V-8-S-8C-E-VM-FW-B-10 |
| NFPA Size | D08 |
| No. of Stages | Two Stage |
| Valve Type | Standard-Duty |
| Electrical Options | None |
| Spool Control Modification Code | None |
| Body Material | Ductile Iron |
| Mounting | Subplate/Manifold Mount |
| Solenoid | Double |
| Indicator Lights | No |
| Electrical Connector Code | None |
| Center Position | P to T, A & B Blocked |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Solenoid Energization Code | V |
| Actuation Identification | Solenoid A, Solenoid B |
| Port T Pressure Rating | 5000 psi |
| Manual Override Option Code | None |
| Solenoid Indicator Lights Code | None |
| Coil Rating Code | B |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Actuator Type | Solenoid |
| Function | 3-Position Spring Centered |
| Gauge Ports Code | None |
| Coil Type Code | F |
| Electrical Options Code | None |
| Overrides | Plain Override Solenoid Ends |
| Manual Override | Plain Override |
| Gauge Port | SAE-4 |
| Spool Indicator Switch Code | None |
| Spool Spring Arrangement Code | C |
| Operation | Pilot Operated |
| Tank Port Rating | 5000 |
| Design No. | 10 |
| Crossover | All Ports Open, Restricted |
| Pilot Valve Type Code | S |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Weight | 35.0 LB |