Vickers by Danfoss02-329265

02-329265

Vickers D08 Solenoid Valve
Item #101978001
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329265
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Response Type Code None
AC/DC AC
Coil Rating Code B
Center Position P to T, A & B Blocked
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Leakage Standard Performance
Mechanical Options Code None
Port Restrictor Plug Code None
Spool Code 8
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection No Connector
Spool Control Modification Code None
Spool Indicator Switch Code None
Mechanical Options None
Gauge Port SAE-4
Manual Override Option Code None
Mounting Subplate/Manifold Mount
Pilot Valve Type Code S
NFPA Size D08
Performance Standard Performance
EN Code None
Coil Type Code F
Pilot Valve Type CETOP 3, Standard Performance
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper Code None
Reducer Module Code None
Actuator Type Solenoid
Solenoid Double
Operation Pilot Operated
Crossover All Ports Open, Restricted
Manual Override Plain Override
Valve Type Standard-Duty
Spool Spring Arrangement Code C
Pilot/Drain External Pilot/Internal Drain
No. of Stages Two Stage
Model No. DG5V-8-S-8C-E-VM-FW-B-10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Design No. 10
Solenoid Energization Code V
Overrides Plain Override Solenoid Ends
Reducer Module No
Pressure Port Check Valve Code None
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Tank Port Rating 5000
Temperature Range [Min] -40 °F
Housing Code W
Function 3-Position Spring Centered
Gauge Ports Code None
Electrical Options Code None
Indicator Lights No
Electrical Options None
Actuation Identification Solenoid A, Solenoid B
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Temperature Range [Max] 230 °F
Pilot Drain Code None
Seal Material Buna-N
Surge Suppressor/Damper None
Electrical Connector Code None
Pilot Pressure Code E
Body Material Ductile Iron
Port T Pressure Rating 5000 psi
Rated Flow [Max] 175 gal/min
Port Restrictor Plugs None
Solenoid Indicator Lights Code None
Weight 35.0 LB