Vickers by Danfoss02-325845

02-325845

Vickers D08 Solenoid Valve
Item #102084143
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-325845
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Solenoid Energization Code None
Spool Spring Arrangement Code A
Solenoid Single
Actuator Type Solenoid
Manual Override Plain Override
Tank Port Rating 5000
Leakage Standard Performance
No. of Stages Two Stage
Spool Indicator Switch Code None
Compatible Fluids Petroleum Oil
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot/Drain External Pilot/External Drain
Port Restrictor Plug Code None
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Fluid Cleanliness 19/17/14 micron
EN Code None
Spool Control Modification Code None
Pressure Port Check Valve Pressure N/A
Electrical Options None
Temperature Range [Max] 230 °F
Center Position All Ports Open Over Tapers
Reducer Module No
Design No. 10
Surge Suppressor/Damper Code None
Gauge Port SAE-4
Pressure Port Check Valve Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Valve Type CETOP 3, Standard Performance
Solenoid Indicator Lights Code None
Reducer Module Code None
Pilot Pressure Code E
Mechanical Options Code None
Temperature Range [Min] -40 °F
Indicator Lights No
Electrical Connection No Connector
Electrical Options Code None
Crossover All Ports Open
Performance Standard Performance
Model No. DG5V-8-S-9A-E-M-FW-B-10
Coil Type Code F
Actuation Identification Solenoid B
Pilot Valve Type Code S
Coil Rating Code B
Valve Type Standard-Duty
Response Type Code None
Pressure [Max] 5000 psi
Operation Pilot Operated
Surge Suppressor/Damper None
Seal Material Buna-N
Housing Code W
NFPA Size D08
Response Type Standard Response
AC/DC AC
Pilot Drain Code None
Port T Pressure Rating 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Rated Flow [Max] 175 gal/min
Body Material Ductile Iron
Function 2-Position Spring Offset
Spool Code 9
Gauge Ports Code None
Manual Override Option Code None
Mechanical Options None
Mounting Subplate/Manifold Mount
Weight 35.0 LB