description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Solenoid Double
Electrical Connector Code T
Gauge Port SAE-4
Actuator Type Solenoid
Crossover All Ports Blocked
Coil Type Code F
Coil Rating Code B
Housing Code W
Pilot Drain Code T
AC/DC AC
Reducer Module N/A
Mechanical Options Code None
Pilot Pressure Code None
Center Position P & A Blocked, B to T
Tank Port Rating 5000
Mechanical Options None
Model No. DG5V-8-S-31C-T-M-FTWL-B-10
Manual Override Plain Override
Port Restrictor Plug Code None
Pilot Valve Type CETOP 3, Standard Performance
Overrides Plain Override Solenoid Ends
Electrical Connection Wired Terminal Block
Spool Code 31
Gauge Ports Code None
Design No. 10
EN Code None
Reducer Module Code None
Pressure Port Check Valve Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper None
Electrical Options Code None
Electrical Options None
Spool Control Modification Code None
Rated Flow [Max] 185 gal/min
Seal Material Buna-N
Response Type Standard Response
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 5000 psi
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot/Drain Internal Pilot/Internal Drain
Indicator Lights Yes
Pressure [Max] 5000 psi
Spool Indicator Switch Code None
Valve Type Standard-Duty
Spool Spring Arrangement Code C
Manual Override Option Code None
Response Type Code None
Port Restrictor Plugs None
NFPA Size D08
Solenoid Indicator Lights Code L
Operation Pilot Operated
Pilot Valve Type Code S
Function 3-Position Spring Centered
Weight 35.0 LB