- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Rated Flow [Max] | 175 gal/min |
Seal Material | Buna-N |
Compatible Fluids | Petroleum Oil |
Model No. | DG5V-8-S-4C-X-VM-FTWL-B-10 |
Manual Override | Plain Override |
Overrides | Plain Override Solenoid Ends |
Pilot/Drain | Internal Pilot/External Drain |
Temperature Range [Min] | -40 °F |
EN Code | None |
Gauge Ports Code | None |
Mounting | Subplate/Manifold Mount |
Surge Suppressor/Damper | None |
Pilot Valve Type Code | S |
Mechanical Options Code | None |
Spool Indicator Switch Code | None |
Pilot Pressure Code | None |
Housing Code | W |
Response Type Code | X |
Manual Override Option Code | None |
Electrical Options Code | None |
Function | 3-Position Spring Centered |
Electrical Options | None |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Performance | Standard Performance |
Valve Type | Standard-Duty |
Leakage | Standard Performance |
Spool Code | 4 |
Response Type | Fast Response |
Electrical Connector Code | T |
Temperature Range [Max] | 230 °F |
Body Material | Ductile Iron |
Gauge Port | SAE-4 |
Actuator Type | Solenoid |
Design No. | 10 |
Tank Port Rating | 5000 |
Surge Suppressor/Damper Code | None |
Port Restrictor Plugs | None |
Electrical Connection | Wired Terminal Block |
NFPA Size | D08 |
Port Restrictor Plug Code | None |
Solenoid Energization Code | V |
Pilot Valve Type | CETOP 3, Standard Performance |
Mechanical Options | None |
Coil Rating Code | B |
Pressure Port Check Valve Code | None |
Port T Pressure Rating | 5000 psi |
Reducer Module Code | None |
AC/DC | AC |
No. of Stages | Two Stage |
Coil Type Code | F |
Pilot Drain Code | None |
Crossover | All Ports Blocked |
Operation | Pilot Operated |
Pressure Port Check Valve Pressure | N/A |
Reducer Module | No |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Actuation Identification | Solenoid A, Solenoid B |
Indicator Lights | Yes |
Solenoid Indicator Lights Code | L |
Spool Control Modification Code | None |
Center Position | Tandem P to T |
Pressure [Max] | 5000 psi |
Spool Spring Arrangement Code | C |
Solenoid | Double |
Fluid Cleanliness | 19/17/14 micron |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Weight | 35.0 LB |