- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Mechanical Options | None |
Solenoid Energization Code | V |
Compatible Fluids | Petroleum Oil |
Solenoid | Double |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Surge Suppressor/Damper | None |
Body Material | Ductile Iron |
Response Type | Standard Response |
Indicator Lights | Yes |
Manual Override | Plain Override |
Pilot Valve Type Code | S |
Crossover | All Ports Open, Restricted |
Rated Flow [Max] | 175 gal/min |
Electrical Connector Code | T |
Tank Port Rating | 5000 |
Gauge Port | SAE-4 |
Pilot Valve Type | CETOP 3, Standard Performance |
Center Position | P to T, A & B Blocked |
Electrical Options Code | None |
Valve Type | Standard-Duty |
Design No. | 10 |
Overrides | Plain Override Solenoid Ends |
Port T Pressure Rating | 5000 psi |
No. of Stages | Two Stage |
Housing Code | W |
Spool Spring Arrangement Code | C |
Operation | Pilot Operated |
Reducer Module | No |
Coil Rating Code | B |
Response Type Code | None |
Spool Control Modification Code | None |
Mounting | Subplate/Manifold Mount |
Pressure [Max] | 5000 psi |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Electrical Options | None |
Leakage | Standard Performance |
Spool Code | 8 |
Coil Type Code | F |
Surge Suppressor/Damper Code | None |
Solenoid Indicator Lights Code | L |
Reducer Module Code | None |
Fluid Cleanliness | 19/17/14 micron |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Performance | Standard Performance |
EN Code | None |
Manual Override Option Code | None |
Pilot/Drain | External Pilot/Internal Drain |
Gauge Ports Code | None |
Electrical Connection | Wired Terminal Block |
Temperature Range [Max] | 230 °F |
Temperature Range [Min] | -40 °F |
Actuator Type | Solenoid |
Function | 3-Position Spring Centered |
Pressure Port Check Valve Pressure | 75 psi |
Model No. | DG5V-8-S-8C-T-S-VM-FTWL-B-10 |
Mechanical Options Code | None |
Pilot Drain Code | T |
Spool Indicator Switch Code | None |
Pilot Pressure Code | None |
Actuation Identification | Solenoid A, Solenoid B |
NFPA Size | D08 |
Pressure Port Check Valve Code | S |
Seal Material | Buna-N |
Port Restrictor Plug Code | None |
AC/DC | AC |
Port Restrictor Plugs | None |
Weight | 35.0 LB |