Vickers02-329170

02-329170

Vickers D08 Solenoid Valve
Item #101975667
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers02-329170
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Should not be used in other areas such as spindles or gearbox shafting without approval by Torrington Engineering Department.
Seal Material Buna-N
Voltage & Frequency 220/240 VAC - 50/60 Hz
Solenoid Indicator Lights Code None
Coil Type DIN 43650
Solenoid Double
Spool Indicator Switch Code None
Response Type Code None
Model No. DG5V-8-S-6C-M-U-D-10
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Gauge Ports Code None
Surge Suppressor/Damper Code None
AC/DC AC
Gauge Port SAE-4
Reducer Module Code None
Indicator Lights No
Mechanical Options None
Electrical Options None
Manual Override Plain Override
Coil Type Code U
Port Restrictor Plugs None
Housing Code None
Design No. 10
Pressure Port Check Valve Pressure N/A
Pilot Drain Code None
Overrides Plain Override Solenoid Ends
Mechanical Options Code None
Manual Override Option Code None
Operation Pilot Operated
EN Code None
Spool Spring Arrangement Code C
Pilot Valve Type Code S
Actuator Type Solenoid
Electrical Connector Code None
Solenoid Energization Code None
Electrical Options Code None
Surge Suppressor/Damper None
Tank Port Rating 5000
Coil Rating Code D
Function 3-Position Spring Centered
Spool Code 6
Rated Flow [Max] 185 gal/min
Pilot Valve Type CETOP 3, Standard Performance
Electrical Connection No Connector
Response Type Standard Response
Crossover P Blocked, A or B to T
Port T Pressure Rating 5000 psi
Reducer Module N/A
Spool Control Modification Code None
Pilot/Drain External Pilot/Internal Drain
Center Position P Blocked, A & B to T
NFPA Size D08
Pilot Pressure Code None
Weight 35.0 LB