- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Body Material | Gray Iron |
| Surge Suppressor/Damper | None |
| Indicator Lights | No |
| Model No. | DG4S4-016A-50-LH |
| Seal Material | Buna-N |
| Response Type | Standard Response |
| Rated Flow [Max] | 24 gal/min |
| Pressure [Max] | 12000 psi |
| Actuator Type | Solenoid |
| Tank Port Rating | 1000 |
| Function | 2-Position Spring Offset |
| Spool Code | 6 |
| Electrical Options Code | None |
| Pilot Valve Type | N/A |
| Valve Type | Standard-Duty |
| Operation | Solenoid Operated |
| Solenoid Air Gap Code | None |
| No. of Stages | Single Stage |
| Voltage & Frequency | 115 VAC - 60 Hz |
| Center Position | P Blocked, A & B to T |
| Cycle Rate [Max] | N/A |
| Temperature Range [Max] | 122 °F |
| Spool Spring Arrangement Code | A |
| Solenoid | Single |
| Reducer Module | N/A |
| Temperature Range [Min] | 68 °F |
| Mechanical Options | Single Solenoid Reverse Assembly |
| Pressure Port Check Valve Pressure | N/A |
| AC/DC | AC |
| Mounting | Subplate/Manifold Mount |
| Flow Direction Code | 4 |
| NFPA Size | D05 |
| Coil Rating Code | None |
| Compatible Fluids | Petroleum Oil |
| Crossover | P Blocked, A or B to T |
| Actuation Identification | Solenoid B |
| Performance | Standard Performance |
| Fluid Cleanliness | 19/17/14 micron |
| Manual Override | Plain Override |
| Electrical Options | None |
| Coil Type | No Coil |
| Pilot/Drain | None |
| Port Restrictor Plugs | None |
| Electrical Connection | Ground Terminal |
| Port T Pressure Rating | 1000 psi |
| Mechanical Options Code | LH |
| Leakage | Standard Performance |
| Overrides | No Overrides |
| Design No. | 50 |
| Weight | 10.0 LB |