Vickers by Danfoss02-391063

02-391063

Vickers D08 Solenoid Valve
Item #101908260
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-391063
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Function 3-Position Spring Centered
AC/DC AC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
Crossover All Ports Open
Gauge Port SAE-4
Operation Pilot Operated
Pilot/Drain Internal Pilot/External Drain
Electrical Connector Code None
Manual Override Option Code None
Mechanical Options Code None
Seal Material Buna-N
Compatible Fluids Petroleum Oil
Manual Override Plain Override
Model No. DG5V-8-H-0C-S-M-FW-B-10
Port T Pressure Rating 5000 psi
Overrides Plain Override Solenoid Ends
Mounting Subplate/Manifold Mount
Gauge Ports Code None
Coil Rating Code B
Indicator Lights No
Electrical Connection No Connector
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Valve Type Standard-Duty
Port Restrictor Plug Code None
Pressure [Max] 5000 psi
Performance High Performance
EN Code None
Housing Code W
Pressure Port Check Valve Code S
Electrical Options Code None
Pressure Port Check Valve Pressure 75 psi
Pilot Valve Type CETOP 3, High Performance
Electrical Options None
Reducer Module Code None
Pilot Drain Code None
Solenoid Indicator Lights Code None
Body Material Ductile Iron
Design No. 10
Temperature Range [Max] 230 °F
Spool Indicator Switch Code None
Coil Type Code F
Solenoid Double
Pilot Valve Type Code H
No. of Stages Two Stage
Spool Control Modification Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options None
Leakage High Performance
Port Restrictor Plugs None
Tank Port Rating 5000
Temperature Range [Min] -40 °F
Pilot Pressure Code None
Spool Code 0
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Response Type Code None
Actuation Identification Solenoid A, Solenoid B
Spool Spring Arrangement Code C
NFPA Size D08
Solenoid Energization Code None
Center Position All Ports Open
Actuator Type Solenoid
Response Type Standard Response
Weight 35.0 LB