- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- These hoses can be used to convey hazardous chemicals, steam, hot liquids or other dangerous materials which can cause death, serious bodily injury including burns, pressure wounds or chemical exposure if released accidentally. They should, therefore, onl
| Function | 3-Position Detented |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Electrical Options | None |
| Mechanical Options | None |
| No. of Stages | Two Stage |
| Gauge Port | SAE-4 |
| Actuator Type | Solenoid |
| Reducer Module Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| Model No. | DG5V-8-S-2N-T-M-U-B-10 |
| Pressure [Max] | 5000 psi |
| Mechanical Options Code | None |
| Mounting | Subplate/Manifold Mount |
| Spool Spring Arrangement Code | N |
| Body Material | Ductile Iron |
| Pilot Drain Code | T |
| NFPA Size | D08 |
| Coil Type Code | U |
| Reducer Module | No |
| Crossover | All Ports Blocked |
| Manual Override | Plain Override |
| Center Position | All Ports Blocked |
| Leakage | Standard Performance |
| Solenoid Indicator Lights Code | None |
| Electrical Options Code | None |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Indicator Lights | No |
| Operation | Pilot Operated |
| Response Type Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Spool Control Modification Code | None |
| Seal Material | Buna-N |
| Tank Port Rating | 5000 |
| Port T Pressure Rating | 5000 psi |
| Spool Indicator Switch Code | None |
| Solenoid Energization Code | None |
| Surge Suppressor/Damper | None |
| Pilot Valve Type Code | S |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Connection | No Connector |
| Overrides | Plain Override Solenoid Ends |
| Gauge Ports Code | None |
| Port Restrictor Plug Code | None |
| Compatible Fluids | Petroleum Oil |
| Coil Rating Code | B |
| Surge Suppressor/Damper Code | None |
| Manual Override Option Code | None |
| Response Type | Standard Response |
| Spool Code | 2 |
| Temperature Range [Max] | 230 °F |
| Temperature Range [Min] | -40 °F |
| Electrical Connector Code | None |
| AC/DC | AC |
| Port Restrictor Plugs | None |
| Rated Flow [Max] | 175 gal/min |
| Solenoid | Double |
| Pressure Port Check Valve Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Design No. | 10 |
| EN Code | None |
| Valve Type | Standard-Duty |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Pilot Pressure Code | None |
| Performance | Standard Performance |
| Housing Code | None |
| Weight | 35.0 LB |

