Vickers by Danfoss02-336844

02-336844

Vickers D08 Solenoid Valve
Item #101977824
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-336844
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
EN Code None
Model No. DG5V-8-H-6C-T-M-U-A-10
Pilot Pressure Code None
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Electrical Options Code None
Port Restrictor Plug Code None
Coil Type Code U
NFPA Size D08
Port Restrictor Plugs None
Tank Port Rating 5000
Pilot Valve Type Code H
Indicator Lights No
Voltage & Frequency 110 VAC - 50 Hz
AC/DC AC
Spool Control Modification Code None
Center Position P Blocked, A & B to T
Operation Pilot Operated
Response Type Standard Response
Pilot/Drain External Pilot/Internal Drain
Electrical Connection No Connector
Reducer Module Code None
Pilot Valve Type CETOP 3, High Performance
Pressure Port Check Valve Pressure N/A
Coil Type DIN 43650
Gauge Port SAE-4
Solenoid Energization Code None
Gauge Ports Code None
Manual Override Option Code None
Spool Code 6
Coil Rating Code A
Actuator Type Solenoid
Electrical Options None
Pressure Port Check Valve Code None
Housing Code None
Port T Pressure Rating 5000 psi
Valve Type Standard-Duty
Seal Material Buna-N
Crossover P Blocked, A or B to T
Pilot Drain Code T
Surge Suppressor/Damper None
Spool Spring Arrangement Code C
Mechanical Options None
Solenoid Indicator Lights Code None
Design No. 10
Rated Flow [Max] 185 gal/min
Pressure [Max] 5000 psi
Solenoid Double
Spool Indicator Switch Code None
Mechanical Options Code None
Manual Override Plain Override
Reducer Module N/A
Response Type Code None
Function 3-Position Spring Centered
Surge Suppressor/Damper Code None
Weight 35.0 LB