Skip to content Skip to navigation menu
Vickers by Danfoss02-329106

02-329106

Vickers D08 Solenoid Valve
Item #101978257
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329106
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
NFPA Size D08
Port Restrictor Plug Code None
EN Code None
Surge Suppressor/Damper Code None
Crossover All Ports Blocked
Indicator Lights Yes
Electrical Options None
Solenoid Double
No. of Stages Two Stage
Coil Rating Code B
Temperature Range [Min] -40 °F
Gauge Port SAE-4
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
AC/DC AC
Response Type Code None
Pilot/Drain Internal Pilot/External Drain
Pressure Port Check Valve Pressure N/A
Electrical Options Code None
Spool Spring Arrangement Code C
Pilot Valve Type Code S
Tank Port Rating 5000
Solenoid Indicator Lights Code L
Spool Indicator Switch Code None
Pressure [Max] 5000 psi
Model No. DG5V-8-S-2C-2-M-FTWL-B-10
Pilot Drain Code None
Manual Override Plain Override
Seal Material Buna-N
Leakage Standard Performance
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper None
Performance Standard Performance
Temperature Range [Max] 230 °F
Pilot Valve Type CETOP 3, Standard Performance
Operation Pilot Operated
Design No. 10
Manual Override Option Code None
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Reducer Module No
Gauge Ports Code None
Reducer Module Code None
Spool Control Modification Code 2
Center Position All Ports Blocked
Pilot Pressure Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Body Material Ductile Iron
Pressure Port Check Valve Code None
Function 3-Position Spring Centered
Housing Code W
Rated Flow [Max] 175 gal/min
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Compatible Fluids Petroleum Oil
Port T Pressure Rating 5000 psi
Coil Type Code F
Fluid Cleanliness 19/17/14 micron
Mechanical Options Code None
Spool Code 2
Solenoid Energization Code None
Electrical Connector Code T
Valve Type Standard-Duty
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Standard Response
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Electrical Connection Wired Terminal Block
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison