- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| NFPA Size | D08 |
| Port Restrictor Plug Code | None |
| EN Code | None |
| Surge Suppressor/Damper Code | None |
| Crossover | All Ports Blocked |
| Indicator Lights | Yes |
| Electrical Options | None |
| Solenoid | Double |
| No. of Stages | Two Stage |
| Coil Rating Code | B |
| Temperature Range [Min] | -40 °F |
| Gauge Port | SAE-4 |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| AC/DC | AC |
| Response Type Code | None |
| Pilot/Drain | Internal Pilot/External Drain |
| Pressure Port Check Valve Pressure | N/A |
| Electrical Options Code | None |
| Spool Spring Arrangement Code | C |
| Pilot Valve Type Code | S |
| Tank Port Rating | 5000 |
| Solenoid Indicator Lights Code | L |
| Spool Indicator Switch Code | None |
| Pressure [Max] | 5000 psi |
| Model No. | DG5V-8-S-2C-2-M-FTWL-B-10 |
| Pilot Drain Code | None |
| Manual Override | Plain Override |
| Seal Material | Buna-N |
| Leakage | Standard Performance |
| Mounting | Subplate/Manifold Mount |
| Surge Suppressor/Damper | None |
| Performance | Standard Performance |
| Temperature Range [Max] | 230 °F |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Operation | Pilot Operated |
| Design No. | 10 |
| Manual Override Option Code | None |
| Port Restrictor Plugs | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Reducer Module | No |
| Gauge Ports Code | None |
| Reducer Module Code | None |
| Spool Control Modification Code | 2 |
| Center Position | All Ports Blocked |
| Pilot Pressure Code | None |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Body Material | Ductile Iron |
| Pressure Port Check Valve Code | None |
| Function | 3-Position Spring Centered |
| Housing Code | W |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Compatible Fluids | Petroleum Oil |
| Port T Pressure Rating | 5000 psi |
| Coil Type Code | F |
| Fluid Cleanliness | 19/17/14 micron |
| Mechanical Options Code | None |
| Spool Code | 2 |
| Solenoid Energization Code | None |
| Electrical Connector Code | T |
| Valve Type | Standard-Duty |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Response Type | Standard Response |
| Overrides | Plain Override Solenoid Ends |
| Actuator Type | Solenoid |
| Electrical Connection | Wired Terminal Block |
| Weight | 35.0 LB |