Skip to content Skip to navigation menu
Vickers by Danfoss02-143881

02-143881

Vickers D07 Solenoid Valve
Item #102089377
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-143881
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Spool Code 31
Electrical Options Code None
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Spool Indicator Switch Code None
Mechanical Options None
Rated Flow [Max] 60 gal/min
Pilot Drain Code T
Pressure Port Check Valve Pressure N/A
Assembly Code None
Solenoid Double
Voltage & Frequency 24 VDC
Solenoid Energization Code None
Electrical Connection No Connector
Surge Suppressor/Damper None
Reducer Module N/A
Port T Pressure Rating 1450 psi
Spool Spring Arrangement Code C
Pilot Pressure Code None
Center Position P & A Blocked, B to T
Port Restrictor Plugs None
Manual Override Plain Override
Port Restrictor Plug Code None
Coil Type Code U
Crossover All Ports Blocked
Design No. 60
Housing Code None
Pilot Valve Type N/A
Seal Material Buna-N
Electrical Options None
Pilot/Drain Internal Pilot/Internal Drain
Response Type Standard Response
Electrical Connector Code None
Indicator Lights No
Mounting Screw Option Code N/A
Function 3-Position Spring Centered
Response Type Code None
EN Code None
Coil Type DIN 43650
Coil Rating Code H
Manual Override Option Code None
Operation Pilot Operated
Model No. DG5S4-0431C-T-M-U-H5-60
Tank Port Rating 1450
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Pressure Port Check Valve Code None
NFPA Size D07
Pressure [Max] 3000 psi
Spool Control Modification Code None
Pilot Valve Tank Pressure Rating Code 5
AC/DC DC
Weight 15.0 LB