Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Mounting
Rigid Base
Design
B
Useable at 208V
No
Efficiency Group
Premium Efficient
Product Line
RG
C Dimension
28.61 in
Type
X1050M
Full Load Amps
30.5
VoltCode
U
Substitute Motor
M7058T
Motor Shaft Size
1 7/8 in
Open End Bearing
6309
Rotation
R
Phase
Three Phase
Brake Feature
No
Full Load Pf
82
RefPicture
EM7064T
Voltage Rating
190, 460, 230, 380
Washdown Duty
No
Hz
60 Hz, 50 Hz
Frame
284T
BALD Family Names
Premium Efficient, Explosion Proof
Motor Application
Explosion Proof
Mounting Style
F-1
Service Factor
1
Frame Size
Shaft Input, Not a C-Face
Full Load Efficiency
93.6 %
Poles
4
Voltage
190/380/230/460
Drive End Bearing
6311
Frame Material
Cast Iron
Motor Shaft Length
4 5/8 in
Enclosure
XPFC
RPM
1800 rpm, 1500 rpm
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Full Load rpm
1470 rpm, 1780 rpm
Mult. Sym.
L1
Weight
537.0 LB
EAN or UPC
781568139240
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back