Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Open End Bearing
6309
Brake Feature
No
Product Line
RG
Motor Shaft Length
4 5/8 in
Mounting
Rigid Base
Poles
4
Hz
60 Hz, 50 Hz
Voltage Rating
190, 460, 230, 380
Drive End Bearing
6311
Voltage
190/380/230/460
Phase
Three Phase
Frame
284T
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Rotation
R
Full Load Amps
30.5
Motor Application
Explosion Proof
BALD Family Names
Premium Efficient, Explosion Proof
Efficiency Group
Premium Efficient
Washdown Duty
No
Full Load rpm
1470 rpm, 1780 rpm
Full Load Efficiency
93.6 %
RPM
1800 rpm, 1500 rpm
Useable at 208V
No
Motor Shaft Size
1 7/8 in
Service Factor
1
Mult. Sym.
L1
Design
B
Full Load Pf
82
RefPicture
EM7064T
Frame Material
Cast Iron
C Dimension
28.61 in
Frame Size
Shaft Input, Not a C-Face
Substitute Motor
M7058T
Enclosure
XPFC
Type
X1050M
Mounting Style
F-1
VoltCode
U
Weight
537.0 LB
EAN or UPC
781568139240
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back