Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Substitute Motor
M2549T
Full Load Efficiency
94.5 %
Motor Shaft Size
1 7/8 in
Mult. Sym.
L1
Enclosure
OPSB
Epact Nominal Full Load Efficiency
93 %
RefPicture
ODP3P
Voltage Rating
460, 230
Frame Size
Shaft Input, Not a C-Face
Rotation
R
BALD Family Names
Premium Efficient, Nema Premium™
Hz
60 Hz
Efficiency Group
Premium Efficient
Motor Application
General Purpose
Washdown Duty
No
Drive End Bearing
6313
Voltage
230/460
Frame
364TS
Useable at 208V
No
Brake Feature
No
Type
4254M
Phase
Three Phase
Full Load Pf
91
Product Line
RG
Mounting Style
F-1
RPM
3600 rpm
Design
B
C Dimension
27.56 in
Mounting
Rigid Base
Frame Material
Steel
Full Load rpm
3540 rpm
Open End Bearing
6311
Full Load Amps
82
Motor Shaft Length
3 3/4 in
Enclosure Designation
OPSB - Open Slotted Band
Service Factor
1.15
Poles
2
VoltCode
F
C Face Kit
14-1401
Weight
507.0 LB
EAN or UPC
781568105283
NEMA Premium
My Applied Catalog