Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Shaft Length
5 1/4 in
Hz
60 Hz
Voltage Rating
575
Frame Size
Shaft Input, Not a C-Face
VoltCode
H
Full Load rpm
1775 rpm
Frame
326T
Useable at 208V
No
Product Line
RG
Design
B
Mounting Style
F-1
RPM
1800 rpm
Drive End Bearing
6312
Efficiency Group
Premium Efficient
Motor Application
General Purpose, Premium Efficient
Type
4256M
Mult. Sym.
L1
BALD Family Names
Premium Efficient, Nema Premium™
Full Load Pf
87
Service Factor
1.15
Voltage
575
Rotation
R
Brake Feature
No
Full Load Efficiency
94.5 %
Substitute Motor
M2543T-5
RefPicture
EMDP
Washdown Duty
No
Poles
4
Mounting
Rigid Base
C Dimension
27.69 in
Full Load Amps
46
Enclosure Designation
OPSB - Open Slotted Band
Open End Bearing
6311
Enclosure
OPSB
Phase
Three Phase
Motor Shaft Size
2 1/8 in
Weight
465.0 LB
EAN or UPC
781568118788
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back