Vickers D03 Solenoid Valve

859183

Vickers D03 Solenoid Valve
Item #101922876
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Multi-fluid capability without the need to change seals
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Temperature Range [Max] 158 °F
Coil Type Code U
Function Code 6
Tank Port Rating 3046
Manual Override Option Code None
Electrical Connection DIN 43650
Coil Type ISO 4400
Manual Override Plain Override
Center Position P Blocked, A & B to T
Port T Code 7
Pilot/Drain None
No. of Stages Single Stage
Voltage & Frequency 24 VDC
Mechanical Options None
Port Restrictor Plug Code None
Solenoid Indicator Lights Code None
Actuation Identification Solenoid A, Solenoid B
Compatible Fluids Petroleum Oil
Coil Rating Code H
Spool Spring Arrangement Code C
Function 3-Position Spring Centered
Temperature Range [Min] -4 °F
Performance High Performance
Solenoid Double
Port Restrictor Plugs None
Mounting Subplate/Manifold Mount
Spool Indicator Switch Code None
Leakage Standard Performance
Reducer Module No
Fluid Cleanliness 19/17/14 micron
Port T Pressure Rating 3000 psi
Spool Code 6
Valve Type High-Performance
Electrical Connector Code None
Crossover P Blocked, A or B to T
Spool Shift Timing N/A
Response Time 28 to 45 ms
EN Code None
Solenoid Energization Code V
Model No. DG4V 3 6C VM U H7 60
Surge Suppressor/Damper None
Response Type Standard Response
Operation Solenoid Operated
NFPA Size D03
Rated Flow [Max] 20 gal/min
AC/DC DC
Surge Suppressor/Damper Code None
Electrical Options None
Indicator Lights No
Cycle Rate [Max] N/A
Housing Code None
Pilot Valve Type N/A
Solenoid Code H
Watt Rating 30 W
Actuator Type Solenoid
Design No. 60
Body Material Gray Iron
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Overrides No Overrides
Pressure [Max] 5000 psi
Weight 5.0 LB