- Flow Control Valve
- Flow Divider/Combiner Type
- FDC1-16 Series
- 12 gal/min Minimum Flow
- 47 gal/min Maximum Flow
description
- Pressure-compensated, spool-type, screw-in, flow divider/combiner cartridge. This valve is used in the dividing mode. It will take the inlet flow (port 3) and split the flow according to the ratio specified, regardless of system pressure to ports 2 and 4. In the combining mode this valve will take the inlet flows from ports 2 and 4 and combine them into port 3 according to the ratio specified.
caution
- Steel housings must be used for operating pressures above 210 bar (3,000 psi)
| Seal Material | Buna-N |
| Port Type | Cartridge Only |
| Model No. | FDC1-16-0-44 |
| Manufacturer Part No. | FDC1-16-0-44 |
| Type | Flow Divider/Combiner |
| No. of Valve Ports | 4 |
| Leakage | Standard |
| Installation | Screw-in Cartridge |
| Pressure [Max] | 3000 psi |
| Seal Kit Buna | 889634 |
| Temperature Range [Min] | -40 °F |
| Flow [Max] | 47 gal/min |
| Body Type | 10 |
| Operation | Direct Acting |
| Seal Kit Viton | 889638 |
| Temperature Range [Max] | 248 °F |
| Valve Material | Cartridge only |
| Divider Flow | 24 gal/min |
| No. of Housing Ports | 4 |
| Cavity | C-16-4 |
| Series | FDC1-16 |
| Flow [Min] | 12 gal/min |
| Style | Spool |
| Housing Material | Aluminum |
| Valve Torque into Cavity | 108 to 122 Nm |
| Recommend Filtration Level | 18/16/13 microns |
| Weight | 0.78 LB |