Vickers D03 Solenoid Valve

02-364441

Vickers D03 Solenoid Valve
Item #101905783
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 3-Position Detented
Performance High Performance
Reducer Module No
Solenoid Energization Code None
Pilot/Drain None
Spool Spring Arrangement Code N
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Mounting Subplate/Manifold Mount
Spool Code 2
Mechanical Options None
Electrical Connector Code None
Tank Port Rating 3046
Solenoid Double
Actuation Identification Solenoid A, Solenoid B
Valve Type High-Performance
AC/DC DC
Operation Solenoid Operated
Voltage & Frequency 24 VDC
Leakage Standard Performance
Port Restrictor Plug Code None
Electrical Options None
Actuator Type Solenoid
Indicator Lights No
Temperature Range [Min] -4 °F
Port T Pressure Rating 3000 psi
Fluid Cleanliness 19/17/14 micron
Manual Override Option Code None
Function Code 2
Temperature Range [Max] 158 °F
Manual Override Plain Override
Body Material Gray Iron
Spool Indicator Switch Code None
Pilot Valve Type N/A
Crossover All Ports Blocked
Port Restrictor Plugs None
Seal Material Buna-N
Response Type Standard Response
Port T Code 7
Model No. DG4V-3-2N-M-FW-H7-60-EN21
Response Time 28 to 45 ms
Overrides No Overrides
Solenoid Code H
No. of Stages Single Stage
Housing Code W
Rated Flow [Max] 20 gal/min
Solenoid Indicator Lights Code None
Surge Suppressor/Damper Code None
Electrical Connection No Connector
Spool Shift Timing N/A
Center Position All Ports Blocked
Coil Rating Code H
NFPA Size D03
Compatible Fluids Petroleum Oil
Coil Type Code F
Surge Suppressor/Damper None
Watt Rating 30 W
Cycle Rate [Max] N/A
Pressure [Max] 5000 psi
Pressure Port Check Valve Pressure N/A
Design No. 60
EN Code EN21
Weight 5.0 LB