Vickers D08 Solenoid Valve
Item #101909346
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-362563
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Indicator Lights No
Spool Code 8
Design No. 10
Manual Override Plain Override
Function 3-Position Spring Centered
Model No. DG5V-8-H-8C-2-R-VM-FW-B-10
Pilot Valve Type Code H
Pilot/Drain External Pilot/Internal Drain
Crossover All Ports Open, Restricted
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Valve Type Standard-Duty
Surge Suppressor/Damper None
Gauge Port SAE-4
Spool Spring Arrangement Code C
AC/DC AC
Pilot Drain Code None
Manual Override Option Code None
Pilot Pressure Code None
Solenoid Indicator Lights Code None
Coil Type Code F
Housing Code W
Port Restrictor Plugs None
Solenoid Energization Code V
Actuator Type Solenoid
Electrical Connection No Connector
Reducer Module Code None
Center Position P to T, A & B Blocked
Mechanical Options Adjust Pilot Chokes on Both Ends
Electrical Connector Code None
EN Code None
Solenoid Double
Pressure Port Check Valve Pressure 50 psi
Operation Pilot Operated
Pressure Port Check Valve Code R
Spool Control Modification Code 2
Pilot Valve Type CETOP 3, High Performance
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options Code None
Tank Port Rating 5000
Electrical Options Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Port T Pressure Rating 5000 psi
NFPA Size D08
Rated Flow [Max] 185 gal/min
Response Type Standard Response
Coil Rating Code B
Reducer Module N/A
Electrical Options None
Gauge Ports Code None
Spool Indicator Switch Code None
Response Type Code None
Weight 35.0 LB