Vickers D03 Solenoid Valve

02-354516

Vickers D03 Solenoid Valve
Item #101985629
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Model No. DG4V-3S-2A-M-FPA5WL-B5-60-P08
Port Restrictor Plugs 0.8 mm Diameter - P Port
Port T Pressure Rating 1500 psi
Overrides No Overrides
Electrical Connector Code PA5
Function 2-Position Spring Offset, End to End
AC/DC AC
Design No. 60
NFPA Size D03
Mechanical Options None
Spool Code 2
Electrical Connection Five Pin Connector
Solenoid Single
Cycle Rate [Max] N/A
Valve Type Standard-Duty
Seal Material Buna-N
Temperature Range [Max] 158 °F
Actuator Type Solenoid
Indicator Lights Yes
Fluid Cleanliness 19/17/14 micron
Coil Type Code F
Pressure [Max] 5000 psi
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 1450
Port T Code 5
Actuation Identification Solenoid B
Body Material Gray Iron
Port Restrictor Plug Code P08
Pilot/Drain None
Manual Override Option Code None
Surge Suppressor/Damper None
Rated Flow [Max] 10 gal/min
Temperature Range [Min] -4 °F
Leakage Standard Performance
Solenoid Indicator Lights Code L
Housing Code W
Pilot Valve Type N/A
Surge Suppressor/Damper Code None
Spool Spring Arrangement Code A
Center Position All Ports Blocked
Coil Rating Code B
Spool Indicator Switch Code None
Reducer Module No
Response Type Standard Response
EN Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Energization Code None
Solenoid Code B
Manual Override Plain Override
Spool Shift Timing N/A
Operation Solenoid Operated
Performance Standard Performance
Pressure Port Check Valve Pressure N/A
Compatible Fluids Petroleum Oil
Response Time 18 to 32 ms
Function Code 2
Electrical Options None
Crossover All Ports Blocked
Weight 5.0 LB