Vickers by Danfoss02-344750

02-344750

Vickers D08 Solenoid Valve
Item #102094933
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344750
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Do not restrict the inlet flow
Indicator Lights No
Pilot Drain Code None
Port Restrictor Plug Code None
Pilot Pressure Code None
Response Type Code None
Model No. DG5V-8-H-2C-3-M-U-H-10
Gauge Ports Code None
Pressure [Max] 5000 psi
Valve Type Standard-Duty
Manual Override Plain Override
Pilot Valve Type Code H
Electrical Options Code None
AC/DC DC
Reducer Module Code None
Center Position All Ports Blocked
Pilot/Drain External Pilot/Internal Drain
Coil Type DIN 43650
Housing Code None
Coil Rating Code H
Pressure Port Check Valve Pressure N/A
EN Code None
Spool Code 2
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Pressure Port Check Valve Code None
Electrical Options None
Design No. 10
Solenoid Double
Solenoid Energization Code None
Overrides Plain Override Solenoid Ends
Coil Type Code U
Spool Spring Arrangement Code C
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Port Restrictor Plugs None
Rated Flow [Max] 185 gal/min
Gauge Port SAE-4
Spool Indicator Switch Code None
Operation Pilot Operated
Crossover All Ports Blocked
NFPA Size D08
Electrical Connection No Connector
Function 3-Position Spring Centered
Seal Material Buna-N
Surge Suppressor/Damper Code None
Response Type Standard Response
Electrical Connector Code None
Spool Control Modification Code 3
Actuator Type Solenoid
Manual Override Option Code None
Pilot Valve Type CETOP 3, High Performance
Tank Port Rating 5000
Voltage & Frequency 24 VDC
Mechanical Options Code None
Reducer Module N/A
Solenoid Indicator Lights Code None
Weight 35.0 LB