- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Pressure Port Check Valve Code | K |
| Port T Pressure Rating | 5000 psi |
| Spool Spring Arrangement Code | C |
| Gauge Port | SAE-4 |
| Mechanical Options Code | None |
| Electrical Connector Code | T |
| Housing Code | W |
| Pilot Drain Code | T |
| Function | 3-Position Spring Centered |
| Response Type | Standard Response |
| Port Restrictor Plugs | None |
| Crossover | All Ports Blocked |
| Reducer Module Code | None |
| Spool Code | 2 |
| Pressure Port Check Valve Pressure | 5 psi |
| Spool Indicator Switch Code | None |
| NFPA Size | D08 |
| Design No. | 10 |
| Overrides | Plain Override Solenoid Ends |
| Manual Override Option Code | None |
| Surge Suppressor/Damper | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Pilot Pressure Code | None |
| Model No. | DG5V-8-S-2C-T-K-M-FTWL-B-10 |
| Indicator Lights | Yes |
| Operation | Pilot Operated |
| Manual Override | Plain Override |
| Solenoid Indicator Lights Code | L |
| Mechanical Options | None |
| Electrical Options | None |
| Solenoid Energization Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Valve Type | Standard-Duty |
| Solenoid | Double |
| Actuator Type | Solenoid |
| Reducer Module | N/A |
| Response Type Code | None |
| Rated Flow [Max] | 185 gal/min |
| Seal Material | Buna-N |
| Pressure [Max] | 5000 psi |
| Spool Control Modification Code | None |
| Coil Type Code | F |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Gauge Ports Code | None |
| Coil Rating Code | B |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| EN Code | None |
| Center Position | All Ports Blocked |
| Pilot Valve Type Code | S |
| AC/DC | AC |
| Port Restrictor Plug Code | None |
| Electrical Options Code | None |
| Surge Suppressor/Damper Code | None |
| Tank Port Rating | 5000 |
| Electrical Connection | Wired Terminal Block |
| Weight | 35.0 LB |