- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Pressure Port Check Valve Pressure | N/A |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Leakage | Standard Performance |
| Gauge Ports Code | None |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Spool Code | 6 |
| Reducer Module | No |
| Surge Suppressor/Damper Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Mechanical Options Code | None |
| Electrical Options Code | None |
| Electrical Options | None |
| Spool Indicator Switch Code | None |
| Manual Override | Plain Override |
| Response Type | Standard Response |
| Indicator Lights | No |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pilot Drain Code | T |
| Body Material | Ductile Iron |
| Fluid Cleanliness | 19/17/14 micron |
| Electrical Connection | No Connector |
| No. of Stages | Two Stage |
| Model No. | DG5V-8-S-6C-2-T-M-U-B-10 |
| Mounting | Subplate/Manifold Mount |
| Coil Type Code | U |
| Pilot Valve Type Code | S |
| Port T Pressure Rating | 5000 psi |
| Housing Code | None |
| Crossover | P Blocked, A or B to T |
| Port Restrictor Plugs | None |
| Manual Override Option Code | None |
| Pressure [Max] | 5000 psi |
| Valve Type | Standard-Duty |
| Performance | Standard Performance |
| Overrides | Plain Override Solenoid Ends |
| Solenoid | Double |
| Seal Material | Buna-N |
| Temperature Range [Min] | -40 °F |
| Compatible Fluids | Petroleum Oil |
| AC/DC | AC |
| Port Restrictor Plug Code | None |
| Gauge Port | SAE-4 |
| Temperature Range [Max] | 230 °F |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Spool Control Modification Code | 2 |
| Pressure Port Check Valve Code | None |
| Spool Spring Arrangement Code | C |
| Design No. | 10 |
| NFPA Size | D08 |
| Operation | Pilot Operated |
| Response Type Code | None |
| Rated Flow [Max] | 175 gal/min |
| Function | 3-Position Spring Centered |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid Indicator Lights Code | None |
| EN Code | None |
| Electrical Connector Code | None |
| Surge Suppressor/Damper | None |
| Coil Rating Code | B |
| Solenoid Energization Code | None |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Reducer Module Code | None |
| Actuator Type | Solenoid |
| Pilot Pressure Code | None |
| Center Position | P Blocked, A & B to T |
| Tank Port Rating | 5000 |
| Weight | 35.0 LB |