Vickers by Danfoss02-337593

02-337593

Vickers D08 Solenoid Valve
Item #102220548
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337593
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Metal bowl guards are recommended for all applications
  • To clean polycarbonate bowls, use mild soap and water only
  • do not use cleansing agents such as acetone, benzene, carbon tetrachloride, gasoline, toluene, etc., which damage this plastic
Pilot Valve Type Code S
Spool Spring Arrangement Code C
Pressure [Max] 5000 psi
Electrical Options None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
No. of Stages Two Stage
Spool Indicator Switch Code None
Manual Override Option Code None
Overrides Plain Override Solenoid Ends
Reducer Module No
Valve Type Standard-Duty
Housing Code None
Design No. 10
Function 3-Position Spring Centered
Mechanical Options Adjust Pilot Chokes on Both Ends
Pilot Valve Type CETOP 3, Standard Performance
Pressure Port Check Valve Code None
Compatible Fluids Petroleum Oil
Performance Standard Performance
Electrical Options Code None
Spool Code 8
Temperature Range [Max] 230 °F
Port Restrictor Plug Code None
Pilot Drain Code None
Rated Flow [Max] 175 gal/min
Gauge Port SAE-4
Pilot Pressure Code E
Coil Type ISO 4400 (Din 43650) Connector
Mechanical Options Code None
Model No. DG5V-8-S-8C-2-E-VM-U-B-10
Solenoid Double
Solenoid Indicator Lights Code None
Seal Material Buna-N
Reducer Module Code None
Actuator Type Solenoid
Operation Pilot Operated
Port T Pressure Rating 5000 psi
Manual Override Plain Override
Response Type Standard Response
Electrical Connection No Connector
Center Position P to T, A & B Blocked
Indicator Lights No
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Temperature Range [Min] -40 °F
Surge Suppressor/Damper Code None
Crossover All Ports Open, Restricted
Port Restrictor Plugs None
Coil Rating Code B
Pilot/Drain External Pilot/External Drain
Body Material Ductile Iron
Response Type Code None
Mounting Subplate/Manifold Mount
Gauge Ports Code None
Electrical Connector Code None
Coil Type Code U
Pressure Port Check Valve Pressure N/A
Leakage Standard Performance
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Control Modification Code 2
Tank Port Rating 5000
AC/DC AC
NFPA Size D08
Solenoid Energization Code V
EN Code None
Weight 35.0 LB