Vickers by Danfoss02-337499

02-337499

Vickers D08 Solenoid Valve
Item #101915473
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337499
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • These products are neither tested nor represented as suitable for medical or pharmaceutical uses
Temperature Range [Min] -40 °F
AC/DC AC
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Spool Spring Arrangement Code C
Pilot/Drain Internal Pilot/Internal Drain
Manual Override Option Code None
Solenoid Energization Code V
Gauge Port SAE-4
Electrical Options Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Model No. DG5V-8-S-4C-2-T-S-VM-FW-B-10
Pressure Port Check Valve Code S
Performance Standard Performance
Spool Indicator Switch Code None
Operation Pilot Operated
Body Material Ductile Iron
Temperature Range [Max] 230 °F
Actuation Identification Solenoid A, Solenoid B
Seal Material Buna-N
Port Restrictor Plug Code None
Valve Type Standard-Duty
Crossover All Ports Blocked
Fluid Cleanliness 19/17/14 micron
Gauge Ports Code None
Pilot Pressure Code None
Solenoid Double
Overrides Plain Override Solenoid Ends
Port T Pressure Rating 5000 psi
Surge Suppressor/Damper None
Electrical Connector Code None
Function 3-Position Spring Centered
Spool Control Modification Code 2
Pressure [Max] 5000 psi
Pressure Port Check Valve Pressure 75 psi
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Coil Type Code F
Pilot Valve Type Code S
Coil Rating Code B
Mechanical Options Adjust Pilot Chokes on Both Ends
Response Type Standard Response
Response Type Code None
Housing Code W
Mechanical Options Code None
Rated Flow [Max] 175 gal/min
Reducer Module No
No. of Stages Two Stage
Center Position Tandem P to T
Tank Port Rating 5000
EN Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Design No. 10
Solenoid Indicator Lights Code None
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
Compatible Fluids Petroleum Oil
Electrical Options None
Manual Override Plain Override
NFPA Size D08
Leakage Standard Performance
Pilot Drain Code T
Spool Code 4
Reducer Module Code None
Indicator Lights No
Actuator Type Solenoid
Surge Suppressor/Damper Code None
Weight 35.0 LB