Vickers by Danfoss02-337163

02-337163

Vickers D08 Solenoid Valve
Item #101914339
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-337163
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Not recommended for bias splices, troughed belts where common bar breakage is a concern, and where special metals are not available in Unibar configurations
Manual Override Plain Override
Response Type Standard Response
Mechanical Options Code None
EN Code None
Gauge Ports Code None
Pilot/Drain External Pilot/Internal Drain
Spool Code 2
Design No. 10
Mechanical Options None
Reducer Module N/A
Response Type Code None
Surge Suppressor/Damper None
Tank Port Rating 5000
Pilot Valve Type Code S
Port Restrictor Plug Code None
Spool Control Modification Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Code K
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Valve Type Standard-Duty
Port Restrictor Plugs None
Rated Flow [Max] 185 gal/min
Electrical Connector Code T
Port T Pressure Rating 5000 psi
Coil Type Code F
Coil Rating Code B
NFPA Size D08
Pressure Port Check Valve Pressure 5 psi
Function 3-Position Detented
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code L
Model No. DG5V-8-S-2N-T-K-M-FTWL-B-10
Spool Spring Arrangement Code N
Electrical Options Code None
Crossover All Ports Blocked
Gauge Port SAE-4
Solenoid Energization Code None
Pilot Valve Type CETOP 3, Standard Performance
Reducer Module Code None
Spool Indicator Switch Code None
Center Position All Ports Blocked
Overrides Plain Override Solenoid Ends
Housing Code W
Electrical Connection Wired Terminal Block
Manual Override Option Code None
Electrical Options None
Operation Pilot Operated
Solenoid Double
Pilot Pressure Code None
Pilot Drain Code T
Seal Material Buna-N
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights Yes
Actuator Type Solenoid
AC/DC AC
Weight 35.0 LB