02-330969

Vickers D08 Solenoid Valve
Item #101975650
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-330969
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Port Restrictor Plug Code None
Temperature Range [Min] -40 °F
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Pilot/Drain External Pilot/External Drain
Coil Type ISO 4400 (Din 43650) Connector
Coil Rating Code B
Port Restrictor Plugs None
Solenoid Double
Electrical Options Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Body Material Ductile Iron
Port T Pressure Rating 5000 psi
Design No. 10
Pilot Valve Type CETOP 3, Standard Performance
Crossover All Ports Blocked
Surge Suppressor/Damper None
Housing Code None
Coil Type Code U
Pressure Port Check Valve Code None
Manual Override Option Code None
Temperature Range [Max] 230 °F
Manual Override Plain Override
Electrical Options None
Actuator Type Solenoid
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Mechanical Options None
No. of Stages Two Stage
Spool Code 2
Center Position All Ports Blocked
Tank Port Rating 5000
Pilot Valve Type Code S
Reducer Module Code None
Indicator Lights No
Gauge Port SAE-4
NFPA Size D08
Pilot Drain Code None
EN Code None
Solenoid Indicator Lights Code None
Model No. DG5V-8-S-2C-E-M-U-B-10
Function 3-Position Spring Centered
Reducer Module No
Operation Pilot Operated
Response Type Code None
Mechanical Options Code None
Spool Control Modification Code None
Rated Flow [Max] 175 gal/min
Gauge Ports Code None
AC/DC AC
Electrical Connection No Connector
Spool Spring Arrangement Code C
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
Seal Material Buna-N
Actuation Identification Solenoid A, Solenoid B
Compatible Fluids Petroleum Oil
Performance Standard Performance
Mounting Subplate/Manifold Mount
Response Type Standard Response
Surge Suppressor/Damper Code None
Solenoid Energization Code None
Fluid Cleanliness 19/17/14 micron
Leakage Standard Performance
Spool Indicator Switch Code None
Pilot Pressure Code E
Weight 35.0 LB