- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Spool Indicator Switch Code | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Pressure Port Check Valve Pressure | N/A |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Function | 3-Position Spring Centered |
| Pressure [Max] | 5000 psi |
| Spool Control Modification Code | None |
| Electrical Options | None |
| Mounting | Subplate/Manifold Mount |
| Surge Suppressor/Damper Code | None |
| Port T Pressure Rating | 5000 psi |
| Actuator Type | Solenoid |
| Performance | High Performance |
| Mechanical Options Code | None |
| Reducer Module Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| Seal Material | Buna-N |
| No. of Stages | Two Stage |
| AC/DC | AC |
| Valve Type | Standard-Duty |
| Model No. | DG5V-8-H-2C-M-FW-B-10 |
| Gauge Ports Code | None |
| Electrical Connection | No Connector |
| NFPA Size | D08 |
| Electrical Options Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Spool Spring Arrangement Code | C |
| Gauge Port | SAE-4 |
| Surge Suppressor/Damper | None |
| Solenoid | Double |
| Body Material | Gray Iron |
| Leakage | Standard Performance |
| Crossover | All Ports Blocked |
| Operation | Pilot Operated |
| Mechanical Options | None |
| Center Position | All Ports Blocked |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Solenoid Indicator Lights Code | None |
| Port Restrictor Plug Code | None |
| Coil Type Code | F |
| Manual Override | Plain Override |
| Pilot Pressure Code | None |
| Indicator Lights | No |
| Response Type Code | None |
| Pilot Valve Type Code | H |
| Response Type | Standard Response |
| Design No. | 10 |
| Port Restrictor Plugs | None |
| Reducer Module | No |
| Electrical Connector Code | None |
| Rated Flow [Max] | 175 gal/min |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Manual Override Option Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Tank Port Rating | 5000 |
| Solenoid Energization Code | None |
| Spool Code | 2 |
| EN Code | None |
| Compatible Fluids | Petroleum Oil |
| Housing Code | W |
| Overrides | Plain Override Solenoid Ends |
| Coil Rating Code | B |
| Pilot Drain Code | None |
| Pressure Port Check Valve Code | None |
| Weight | 35.0 LB |