- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Crossover | All Ports Blocked |
| Seal Material | Buna-N |
| Mechanical Options Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| Coil Rating Code | B |
| Electrical Connector Code | PA5 |
| Manual Override Option Code | None |
| Port Restrictor Plugs | None |
| Spool Spring Arrangement Code | C |
| Temperature Range [Min] | -40 °F |
| Pressure Port Check Valve Pressure | N/A |
| Coil Type Code | F |
| Overrides | Plain Override Solenoid Ends |
| Function | 3-Position Spring Centered |
| Rated Flow [Max] | 175 gal/min |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Reducer Module | No |
| Valve Type | Standard-Duty |
| Pilot Pressure Code | None |
| No. of Stages | Two Stage |
| Response Type | Standard Response |
| AC/DC | AC |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Port T Pressure Rating | 5000 psi |
| Performance | Standard Performance |
| Actuation Identification | Solenoid A, Solenoid B |
| NFPA Size | D08 |
| EN Code | None |
| Model No. | DG5V-8-S-2C-2-T-M-FPA5WL-B-10 |
| Operation | Pilot Operated |
| Indicator Lights | Yes |
| Electrical Options Code | None |
| Reducer Module Code | None |
| Electrical Options | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Port Restrictor Plug Code | None |
| Electrical Connection | Five Pin Connector |
| Spool Indicator Switch Code | None |
| Solenoid | Double |
| Pilot Valve Type Code | S |
| Design No. | 10 |
| Center Position | All Ports Blocked |
| Manual Override | Plain Override |
| Gauge Ports Code | None |
| Spool Control Modification Code | 2 |
| Body Material | Ductile Iron |
| Leakage | Standard Performance |
| Solenoid Energization Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Spool Code | 2 |
| Solenoid Indicator Lights Code | L |
| Compatible Fluids | Petroleum Oil |
| Pilot Drain Code | T |
| Pressure Port Check Valve Code | None |
| Response Type Code | None |
| Actuator Type | Solenoid |
| Pressure [Max] | 5000 psi |
| Mounting | Subplate/Manifold Mount |
| Temperature Range [Max] | 230 °F |
| Surge Suppressor/Damper | None |
| Gauge Port | SAE-4 |
| Surge Suppressor/Damper Code | None |
| Housing Code | W |
| Pilot/Drain | External Pilot/Internal Drain |
| Tank Port Rating | 5000 |
| Weight | 35.0 LB |