Vickers by Danfoss02-325891

02-325891

Vickers D08 Solenoid Valve
Item #101977874
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-325891
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Center Position All Ports Blocked
Body Material Ductile Iron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Housing Code W
Pressure [Max] 5000 psi
Surge Suppressor/Damper Code None
Pilot Valve Type CETOP 3, Standard Performance
Performance Standard Performance
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection No Connector
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Seal Material Buna-N
Coil Type Code F
Solenoid Energization Code None
Pilot/Drain External Pilot/Internal Drain
Compatible Fluids Petroleum Oil
Solenoid Single
Electrical Options None
Spool Code 2
Port T Pressure Rating 5000 psi
Response Type Code None
Model No. DG5V-8-S-2A-E-M-FW-B-10
Actuator Type Solenoid
Mechanical Options None
Temperature Range [Max] 230 °F
Actuation Identification Solenoid B
Mounting Subplate/Manifold Mount
Fluid Cleanliness 19/17/14 micron
Mechanical Options Code None
EN Code None
No. of Stages Two Stage
Valve Type Standard-Duty
Rated Flow [Max] 175 gal/min
Design No. 10
Indicator Lights No
Pressure Port Check Valve Pressure N/A
Electrical Options Code None
Function 2-Position Spring Offset
Voltage & Frequency 110/120 VAC - 50/60 Hz
Gauge Ports Code None
Manual Override Option Code None
NFPA Size D08
Coil Rating Code B
Pressure Port Check Valve Code None
Spool Indicator Switch Code None
Pilot Valve Type Code S
Electrical Connector Code None
Port Restrictor Plug Code None
Overrides Plain Override Solenoid Ends
Leakage Standard Performance
Gauge Port SAE-4
Temperature Range [Min] -40 °F
Spool Control Modification Code None
Operation Pilot Operated
Pilot Drain Code None
Manual Override Plain Override
Crossover All Ports Blocked
AC/DC AC
Response Type Standard Response
Tank Port Rating 5000
Spool Spring Arrangement Code A
Reducer Module No
Pilot Pressure Code E
Reducer Module Code None
Port Restrictor Plugs None
Weight 35.0 LB