Vickers D03 Solenoid Valve

02-157389

Vickers D03 Solenoid Valve
Item #102029659
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Design No. 60
Rated Flow [Max] 20 gal/min
Manual Override Plain Override
Solenoid Indicator Lights Code L
Temperature Range [Min] -4 °F
Cycle Rate [Max] N/A
Electrical Connector Code PB
Crossover All Ports Blocked
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Port Restrictor Plugs None
Coil Rating Code B
Operation Solenoid Operated
Function 3-Position Spring Centered
Center Position All Ports Blocked
Mechanical Options None
Surge Suppressor/Damper None
Pilot/Drain None
Spool Shift Timing N/A
Spool Spring Arrangement Code C
Port Restrictor Plug Code None
Solenoid Code B
Overrides No Overrides
Actuator Type Solenoid
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuation Identification Solenoid A, Solenoid B
Solenoid Energization Code None
Coil Type Code F
Port T Code 6
Seal Material Buna-N
EN Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Model No. DG4V-3-2C-H-M-FPBWL-B6-60
Pressure Port Check Valve Pressure N/A
No. of Stages Single Stage
Solenoid Double
Spool Code 2
Housing Code W
Manual Override Option Code H
Compatible Fluids Petroleum Oil
Pilot Valve Type N/A
NFPA Size D03
Body Material Gray Iron
AC/DC AC
Tank Port Rating 3046
Performance High Performance
Reducer Module No
Mounting Subplate/Manifold Mount
Response Type Standard Response
Indicator Lights Yes
Pressure [Max] 5000 psi
Leakage Standard Performance
Function Code 2
Response Time 15 to 23 ms
Electrical Connection Instaplug Male & Female Receptacle
Electrical Options None
Port T Pressure Rating 3000 psi
Fluid Cleanliness 19/17/14 micron
Valve Type High-Performance
Temperature Range [Max] 158 °F
Weight 5.0 LB