Vickers D03 Solenoid Valve

02-157389

Vickers D03 Solenoid Valve
Item #102029659
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Mechanical Options None
Center Position All Ports Blocked
Electrical Connector Code PB
Valve Type High-Performance
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Coil Rating Code B
Housing Code W
Coil Type Code F
Surge Suppressor/Damper None
Design No. 60
Solenoid Indicator Lights Code L
Body Material Gray Iron
Port T Pressure Rating 3000 psi
Electrical Connection Instaplug Male & Female Receptacle
Actuation Identification Solenoid A, Solenoid B
Pilot Valve Type N/A
Solenoid Energization Code None
Fluid Cleanliness 19/17/14 micron
Model No. DG4V-3-2C-H-M-FPBWL-B6-60
Reducer Module No
Response Time 15 to 23 ms
Function Code 2
AC/DC AC
Solenoid Code B
NFPA Size D03
Spool Code 2
Mounting Subplate/Manifold Mount
Indicator Lights Yes
Spool Indicator Switch Code None
Crossover All Ports Blocked
Cycle Rate [Max] N/A
Pilot/Drain None
EN Code None
Port Restrictor Plug Code None
Temperature Range [Min] -4 °F
Manual Override Option Code H
Pressure [Max] 5000 psi
Electrical Options None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port T Code 6
Pressure Port Check Valve Pressure N/A
Performance High Performance
Leakage Standard Performance
Tank Port Rating 3046
Function 3-Position Spring Centered
Manual Override Plain Override
No. of Stages Single Stage
Compatible Fluids Petroleum Oil
Solenoid Double
Operation Solenoid Operated
Temperature Range [Max] 158 °F
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Spool Shift Timing N/A
Overrides No Overrides
Actuator Type Solenoid
Spool Spring Arrangement Code C
Surge Suppressor/Damper Code None
Weight 5.0 LB