Vickers D03 Solenoid Valve

02-156177

Vickers D03 Solenoid Valve
Item #102039634
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
EN Code None
Operation Solenoid Operated
Actuator Type Solenoid
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Seal Material Buna-N
Port T Pressure Rating 3000 psi
Spool Code 6
Reducer Module No
Port T Code 7
Crossover P Blocked, A or B to T
Electrical Options None
Port Restrictor Plugs None
Rated Flow [Max] 20 gal/min
Spool Spring Arrangement Code N
Coil Type Code F
Function 3-Position Detented
Coil Rating Code H
Solenoid Energization Code None
Housing Code W
Leakage Standard Performance
Indicator Lights Yes
Electrical Connection Five Pin Connector
Surge Suppressor/Damper None
Valve Type High-Performance
Spool Shift Timing N/A
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Mechanical Options None
Temperature Range [Max] 158 °F
Center Position P Blocked, A & B to T
Overrides No Overrides
Cycle Rate [Max] N/A
Manual Override Option Code None
Function Code 6
Solenoid Double
Spool Indicator Switch Code None
Actuation Identification Solenoid A, Solenoid B
Response Time 28 to 45 ms
Pilot/Drain None
Surge Suppressor/Damper Code None
Response Type Standard Response
Watt Rating 30 W
Performance High Performance
Pressure Port Check Valve Pressure N/A
Model No. DG4V-3-6N-M-FPA5WL-H7-60
Tank Port Rating 3046
Temperature Range [Min] -4 °F
Compatible Fluids Petroleum Oil
Solenoid Code H
Voltage & Frequency 24 VDC
Solenoid Indicator Lights Code L
Pilot Valve Type N/A
No. of Stages Single Stage
Design No. 60
Body Material Gray Iron
Manual Override Plain Override
NFPA Size D03
Electrical Connector Code PA5
Port Restrictor Plug Code None
AC/DC DC
Weight 5.0 LB