Vickers D03 Solenoid Valve

02-156169

Vickers D03 Solenoid Valve
Item #102032489
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pilot Valve Type N/A
Solenoid Energization Code V
Reducer Module No
Pressure [Max] 5000 psi
Actuation Identification Solenoid A, Solenoid B
Pressure Port Check Valve Pressure N/A
Center Position P Blocked, A & B to T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Mechanical Options None
Coil Type Code F
Body Material Gray Iron
Manual Override Option Code None
Response Type Standard Response
Seal Material Buna-N
Electrical Options None
Surge Suppressor/Damper Code None
Spool Shift Timing N/A
EN Code None
AC/DC AC
Design No. 60
Performance High Performance
Mounting Subplate/Manifold Mount
Valve Type High-Performance
Rated Flow [Max] 20 gal/min
Actuator Type Solenoid
Temperature Range [Max] 158 °F
Pilot/Drain None
Indicator Lights Yes
Surge Suppressor/Damper None
Temperature Range [Min] -4 °F
Solenoid Code B
Leakage Standard Performance
Port Restrictor Plug Code None
Crossover P Blocked, A or B to T
Model No. DG4V 3 6C VM FTWL B6 60
Port Restrictor Plugs None
Manual Override Plain Override
Spool Spring Arrangement Code C
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 3000 psi
Tank Port Rating 3046
No. of Stages Single Stage
Function Code 6
Electrical Connector Code T
Solenoid Indicator Lights Code L
Response Time 15 to 23 ms
Operation Solenoid Operated
Spool Indicator Switch Code None
Cycle Rate [Max] N/A
Housing Code W
Fluid Cleanliness 19/17/14 micron
Overrides No Overrides
Function 3-Position Spring Centered
NFPA Size D03
Electrical Connection Wired Terminal Block
Compatible Fluids Petroleum Oil
Coil Rating Code B
Port T Code 6
Spool Code 6
Solenoid Double
Weight 5.0 LB