Vickers D03 Solenoid Valve

02-148507

Vickers D03 Solenoid Valve
Item #102084570
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
NFPA Size D03
Leakage Standard Performance
EN Code EN21
Response Time 15 to 23 ms
Compatible Fluids Petroleum Oil
Mechanical Options None
Crossover All Ports Blocked
Housing Code W
Port Restrictor Plugs None
Solenoid Double
Solenoid Indicator Lights Code None
Pressure [Max] 5000 psi
Spool Shift Timing N/A
Overrides No Overrides
Pilot Valve Type N/A
Electrical Connector Code None
Performance High Performance
Seal Material Buna-N
Center Position All Ports Blocked
Function 3-Position Detented
Tank Port Rating 3046
Manual Override Option Code None
Temperature Range [Min] -4 °F
Temperature Range [Max] 158 °F
Indicator Lights No
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Energization Code None
Response Type Standard Response
Actuation Identification Solenoid A, Solenoid B
No. of Stages Single Stage
Reducer Module No
Electrical Connection No Connector
Surge Suppressor/Damper Code None
Cycle Rate [Max] N/A
Port T Code 6
Fluid Cleanliness 19/17/14 micron
Design No. 60
AC/DC AC
Surge Suppressor/Damper None
Rated Flow [Max] 20 gal/min
Model No. DG4V-3-2N-M-FW-B6-60-EN21
Spool Indicator Switch Code None
Solenoid Code B
Valve Type High-Performance
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Pressure N/A
Coil Rating Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Body Material Gray Iron
Spool Spring Arrangement Code N
Port T Pressure Rating 3000 psi
Manual Override Plain Override
Operation Solenoid Operated
Port Restrictor Plug Code None
Actuator Type Solenoid
Pilot/Drain None
Coil Type Code F
Function Code 2
Electrical Options None
Spool Code 2
Weight 5.0 LB