Vickers D07 Solenoid Valve
Item #102039983
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-148482
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Model No. DG5S4-040A-M-U-H5-60
Mechanical Options None
Pilot Valve Type N/A
Actuator Type Solenoid
Spool Spring Arrangement Code A
Spool Code 0
Spool Control Modification Code None
Operation Solenoid Operated
Pilot Pressure Code None
Tank Port Rating 1450
Overrides Plain Override Solenoid Ends
Solenoid Energization Code None
Electrical Connector Code None
NFPA Size D07
Electrical Options None
Assembly Code None
Pressure [Max] 3000 psi
Spool Indicator Switch Code None
No. of Stages Two Stage
Mounting Subplate/Manifold Mount
Fluid Cleanliness 19/17/14 micron
Electrical Connection No Connector
Port Restrictor Plugs None
Coil Type ISO 4400 (Din 43650) Connector
Seal Material Buna-N
Function 2-Position Spring Offset
Indicator Lights No
Body Material Gray Iron
Center Position All Ports Open
Actuation Identification Solenoid B
Solenoid Single
Pilot Drain Code None
Response Type Standard Response
Housing Code None
Manual Override Plain Override
Pressure Port Check Valve Pressure N/A
Watt Rating 30 W
Rated Flow [Max] 60 gal/min
Coil Rating Code H
Response Type Code None
Pilot/Drain External Pilot/Internal Drain
Voltage & Frequency 24 VDC
Mounting Screw Option Code N/A
Reducer Module No
Crossover All Ports Open
Valve Type Standard-Duty
Pressure Port Check Valve Code None
Design No. 60
Leakage Standard Performance
Surge Suppressor/Damper None
AC/DC DC
Pilot Valve Tank Pressure Rating Code 5
EN Code None
Manual Override Option Code None
Electrical Options Code None
Port T Pressure Rating 1450 psi
Solenoid Indicator Lights Code None
Coil Type Code U
Spool Center Condition B Port End
Port Restrictor Plug Code None
Weight 15.0 LB