Vickers D03 Solenoid Valve

02-144938

Vickers D03 Solenoid Valve
Item #102096625
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Performance Standard Performance
EN Code None
Electrical Connection DIN 43650
Indicator Lights No
Coil Rating Code B
NFPA Size D03
Spool Indicator Switch Code None
Solenoid Double
Function 3-Position, 4-Way, Spring Centered
Coil Type Code U
Coil Type ISO 4400 (Din 43650) Connector
Seal Material Viton
Mechanical Options None
Mounting Manifold Mount
Model No. DG4V-3-8C-VM-U-B6-61
Body Material Gray Iron
Operation Solenoid Operated
Surge Suppressor/Damper None
Center Position P to T, A & B Blocked
Electrical Connector Code None
Electrical Options None
AC/DC AC
Actuator Type Solenoid
Design No. 61
Temperature Range [Min] -4 °F
Surge Suppressor/Damper Code None
Manufacturer Part No. DG4V 3 8C V M U B6 61
Housing Code None
Spool Shift Timing N/A
Temperature Range [Max] 158 °F
Response Type Standard Response
Function Code 8
Manual Override Option Code None
Rated Flow [Max] 20.00 gal/min
Pilot/Drain None
Pressure Port Check Valve Pressure N/A
Port T Code 6
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port Restrictor Plugs None
Crossover All Ports Open, Restricted
Pressure [Max] 5,075 psi
Cycle Rate [Max] 0
Rated Flow 21.00 gal/min
Solenoid Indicator Lights Code None
Port T Pressure Rating 3000 psi
Valve Type High-Performance
Leakage Standard Performance
No. of Stages Single Stage
Compatible Fluids Phosphate Ester Fluids
Spool Spring Arrangement Code C
Reducer Module No
Solenoid Energization Code V
Port Restrictor Plug Code None
Tank Port Rating 3000
Voltage & Frequency 110/120 VAC - 50/60 Hz
Fluid Cleanliness 19/17/14 micron
Spool Code 8
Overrides No Overrides
Watt Rating 20 W
Solenoid Code B
Pilot Valve Type N/A
Manual Override Plain Override
Weight 4.6 LB