Skip to content Skip to navigation menu
Vickers by Danfoss02-139130

02-139130

Vickers D03 Solenoid Valve
Item #101999989
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers by Danfoss02-139130
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Single
EN Code None
Port T Pressure Rating 3000 psi
Port Restrictor Plug Code None
Spool Shift Timing N/A
Solenoid Code H
Solenoid Energization Code None
NFPA Size D03
Temperature Range [Max] 158 °F
Body Material Gray Iron
Port Restrictor Plugs None
Solenoid Indicator Lights Code None
Electrical Connector Code None
Port T Code 7
Tank Port Rating 3046
Spool Spring Arrangement Code B
Center Position All Ports Open
Actuator Type Solenoid
Pressure Port Check Valve Pressure N/A
Spool Code 0
Overrides No Overrides
Actuation Identification Solenoid B
Cycle Rate [Max] N/A
Electrical Connection No Connector
Reducer Module No
Temperature Range [Min] -4 °F
Housing Code W
Design No. 60
Operation Solenoid Operated
Pilot/Drain None
Indicator Lights No
Pilot Valve Type N/A
Rated Flow [Max] 20 gal/min
Response Time 28 to 45 ms
Manual Override Option Code None
Surge Suppressor/Damper None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Mechanical Options None
Model No. DG4V 3 0B M F W H7 60
Response Type Standard Response
Spool Indicator Switch Code None
Function Code 0
Seal Material Buna-N
Performance High Performance
Crossover All Ports Open
Function 2-Position Spring Offset, End to Center
Watt Rating 30 W
Leakage Standard Performance
No. of Stages Single Stage
Coil Type Code F
Voltage & Frequency 24 VDC
Fluid Cleanliness 19/17/14 micron
AC/DC DC
Compatible Fluids Petroleum Oil
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper Code None
Electrical Options None
Manual Override Plain Override
Coil Rating Code H
Valve Type High-Performance
Pressure [Max] 5000 psi
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison