Vickers D05 Solenoid Valve

02-126141

Vickers D05 Solenoid Valve
Item #101973830
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D05 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Response Time 20 to 40 ms
Coil Rating Code B
Electrical Options None
Manual Override Plain Override
Surge Suppressor/Damper None
Design No. 60
Electrical Connection Lead Wires w/ Terminal Box
Reducer Module N/A
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Coil Type Code None
Coil Type Flying Leads
Body Material Gray Iron
Electrical Options Code LW
Indicator Lights Yes
Actuator Type Solenoid
Pressure [Max] 5000 psi
Valve Type Standard-Duty
Tank Port Rating 1000
Pilot/Drain None
Mechanical Options None
Temperature Range [Max] 122 °F
Actuation Identification Solenoid A, Solenoid B
No. of Stages Single Stage
Rated Flow [Max] 24 gal/min
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Flow Direction Code 4
Temperature Range [Min] 68 °F
AC/DC AC
Port T Pressure Rating 1000 psi
NFPA Size D05
Pilot Valve Type N/A
Crossover P to A or B, T & A or B Blocked
Spool Code 7
Overrides No Overrides
Spool Spring Arrangement Code C
Solenoid Double
Port Restrictor Plugs None
Model No. DG4S4LW-017C-B-60
Center Position P to A & B, T Blocked
Function 3-Position Spring Centered
Compatible Fluids Petroleum Oil
Mounting Subplate/Manifold Mount
Operation Solenoid Operated
Seal Material Buna-N
Leakage Standard Performance
Performance Standard Performance
Cycle Rate [Max] N/A
Mechanical Options Code None
Weight 10.0 LB