Skip to content Skip to navigation menu
Vickers by Danfoss02-119476

02-119476

Vickers D05 Solenoid Valve
Item #101963447
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End To Center Function
Vickers by Danfoss02-119476
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Centered, End To Center Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Response Time 20 to 40 ms
Electrical Connection Lead Wires w/ Terminal Box
Crossover P Blocked, A or B to T
Cycle Rate [Max] N/A
Solenoid Single
Function 2-Position Spring Centered, End To Center
Pressure [Max] 3600 psi
Temperature Range [Max] 122 °F
Actuation Identification Solenoid B
Electrical Options None
Tank Port Rating 1000
No. of Stages Single Stage
Reducer Module N/A
Mounting Subplate/Manifold Mount
Port T Pressure Rating 1000 psi
Mechanical Options None
Actuator Type Solenoid
AC/DC AC
Pressure Port Check Valve Pressure N/A
Electrical Options Code W
Coil Type Flying Leads
Compatible Fluids Petroleum Oil
Leakage Standard Performance
Spool Spring Arrangement Code B
Coil Type Code None
Model No. DG4S4W-016B-B-60
NFPA Size D05
Center Position P Blocked, A & B to T
Flow Direction Code 4
Pilot/Drain None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Manual Override Plain Override
Operation Solenoid Operated
Rated Flow [Max] 24 gal/min
Surge Suppressor/Damper None
Indicator Lights Yes
Response Type Standard Response
Spool Code 6
Valve Type Standard-Duty
Seal Material Buna-N
Pilot Valve Type N/A
Fluid Cleanliness 19/17/14 micron
Coil Rating Code B
Temperature Range [Min] 68 °F
Design No. 60
Mechanical Options Code None
Performance Standard Performance
Overrides No Overrides
Body Material Gray Iron
Weight 10.0 LB