Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-110680

Vickers D03 Solenoid Valve
Item #101951658
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Coil Type Code F
Reducer Module No
Coil Rating Code B
Solenoid Single
Temperature Range [Min] -4 °F
Valve Type Standard-Duty
Voltage & Frequency 110/120 VAC - 50/60 Hz
Fluid Cleanliness 19/17/14 micron
Housing Code W
Overrides No Overrides
Design No. 60
Port Restrictor Plugs None
Center Position P Blocked, A & B to T
Body Material Gray Iron
EN Code None
Performance Standard Performance
Crossover P Blocked, A or B to T
Indicator Lights No
Leakage Standard Performance
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Spool Shift Timing N/A
Solenoid Code B
Manual Override Option Code None
Spool Spring Arrangement Code B
Mounting Subplate/Manifold Mount
Electrical Options None
Compatible Fluids Petroleum Oil
Function 2-Position Spring Offset, End To Center, Left Hand Build
Mechanical Options None
Spool Indicator Switch Code None
Model No. DG4V-3S-6BL-M-FW-B5-60
Actuator Type Solenoid
Electrical Connection No Connector
Electrical Connector Code None
AC/DC AC
Response Time 18 to 32 ms
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Max] 158 °F
No. of Stages Single Stage
Cycle Rate [Max] N/A
Port Restrictor Plug Code None
Port T Pressure Rating 1500 psi
Solenoid Indicator Lights Code None
Solenoid Energization Code None
NFPA Size D03
Pressure [Max] 5000 psi
Function Code 6
Spool Code 6
Port T Code 5
Pilot Valve Type N/A
Actuation Identification Solenoid A
Rated Flow [Max] 10 gal/min
Manual Override Plain Override
Tank Port Rating 1450
Seal Material Buna-N
Pilot/Drain None
Response Type Standard Response
Operation Solenoid Operated
Surge Suppressor/Damper Code None
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison