Vickers D03 Solenoid Valve

02-109568

Vickers D03 Solenoid Valve
Item #101934635
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Design No. 60
Solenoid Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Code F
Model No. DG4V 3S 2C M FPBW B5 60
Housing Code W
Surge Suppressor/Damper Code None
Temperature Range [Min] -4 °F
Pilot/Drain None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Actuation Identification Solenoid A, Solenoid B
Center Position All Ports Blocked
Surge Suppressor/Damper None
Function Code 2
Spool Shift Timing N/A
EN Code None
Manual Override Option Code None
Spool Code 2
Reducer Module No
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plugs None
Leakage Standard Performance
Port T Code 5
Spool Indicator Switch Code None
NFPA Size D03
Overrides No Overrides
Operation Solenoid Operated
Rated Flow [Max] 10 gal/min
Pilot Valve Type N/A
Coil Rating Code B
Port Restrictor Plug Code None
Pressure [Max] 5000 psi
Manual Override Plain Override
Compatible Fluids Petroleum Oil
Tank Port Rating 1450
Valve Type Standard-Duty
Port T Pressure Rating 1500 psi
Solenoid Indicator Lights Code None
Body Material Gray Iron
Temperature Range [Max] 158 °F
Mechanical Options None
Electrical Options None
AC/DC AC
Function 3-Position Spring Centered
Response Type Standard Response
Electrical Connector Code PB
No. of Stages Single Stage
Response Time 18 to 32 ms
Spool Spring Arrangement Code C
Cycle Rate [Max] N/A
Fluid Cleanliness 19/17/14 micron
Solenoid Double
Crossover All Ports Blocked
Performance Standard Performance
Pressure Port Check Valve Pressure N/A
Watt Rating 20 W
Solenoid Energization Code None
Electrical Connection Instaplug Male & Female Receptacle
Indicator Lights No
Actuator Type Solenoid
Weight 5.0 LB