- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Pressure [Max] | 5000 psi |
Model No. | DG5V-8-S-6N-2-M-FTWL-B-10 |
Housing Code | W |
Pilot Drain Code | None |
Electrical Options Code | None |
Spool Control Modification Code | 2 |
Indicator Lights | Yes |
No. of Stages | Two Stage |
Body Material | Ductile Iron |
Spool Spring Arrangement Code | N |
Spool Indicator Switch Code | None |
Actuator Type | Solenoid |
Center Position | P Blocked, A & B to T |
Rated Flow [Max] | 175 gal/min |
Temperature Range [Max] | 230 °F |
Electrical Connector Code | T |
Reducer Module Code | None |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Reducer Module | No |
Pilot/Drain | Internal Pilot/External Drain |
Pilot Valve Type Code | S |
Port Restrictor Plugs | None |
Pressure Port Check Valve Pressure | N/A |
Crossover | P Blocked, A or B to T |
Spool Code | 6 |
Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
Gauge Ports Code | None |
Performance | Standard Performance |
Coil Type Code | F |
Function | 3-Position Detented |
Operation | Pilot Operated |
Design No. | 10 |
Solenoid | Double |
Electrical Connection | Wired Terminal Block |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Voltage & Frequency | 110/120 VAC - 50/60 Hz |
Valve Type | Standard-Duty |
Surge Suppressor/Damper | None |
Seal Material | Buna-N |
Solenoid Indicator Lights Code | L |
Pressure Port Check Valve Code | None |
Mechanical Options Code | None |
AC/DC | AC |
Surge Suppressor/Damper Code | None |
Actuation Identification | Solenoid A, Solenoid B |
Compatible Fluids | Petroleum Oil |
Solenoid Energization Code | None |
EN Code | None |
Tank Port Rating | 5000 |
Electrical Options | None |
Leakage | Standard Performance |
Pilot Valve Type | CETOP 3, Standard Performance |
Fluid Cleanliness | 19/17/14 micron |
Coil Rating Code | B |
Response Type | Standard Response |
Temperature Range [Min] | -40 °F |
Response Type Code | None |
Port T Pressure Rating | 5000 psi |
Pilot Pressure Code | None |
Gauge Port | SAE-4 |
Manual Override | Plain Override |
Overrides | Plain Override Solenoid Ends |
Mounting | Subplate/Manifold Mount |
Port Restrictor Plug Code | None |
NFPA Size | D08 |
Manual Override Option Code | None |
Weight | 35.0 LB |