Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-110415

Vickers D03 Solenoid Valve
Item #101950106
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 110/120 VAC - 50/60 Hz
EN Code None
Solenoid Double
Fluid Cleanliness 19/17/14 micron
Watt Rating 20 W
Mounting Subplate/Manifold Mount
Valve Type High-Performance
Electrical Connection Wired Terminal Block
Solenoid Code B
Function Code 2
Surge Suppressor/Damper None
Mechanical Options None
Cycle Rate [Max] N/A
Manual Override Plain Override
Leakage Standard Performance
Tank Port Rating 3046
Spool Shift Timing N/A
No. of Stages Single Stage
Pressure [Max] 5000 psi
Compatible Fluids Petroleum Oil
AC/DC AC
Performance Standard Performance
Port Restrictor Plug Code None
Solenoid Energization Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
NFPA Size D03
Response Type Standard Response
Reducer Module No
Crossover All Ports Blocked
Coil Type Code F
Center Position All Ports Blocked
Temperature Range [Max] 158 °F
Indicator Lights Yes
Manual Override Option Code None
Rated Flow [Max] 20 gal/min
Electrical Connector Code T
Spool Spring Arrangement Code N
Coil Rating Code B
Pressure Port Check Valve Pressure N/A
Model No. DG4V-3-2N-M-FTWL-B6-60
Port T Code 6
Surge Suppressor/Damper Code None
Temperature Range [Min] -4 °F
Housing Code W
Overrides No Overrides
Spool Code 2
Body Material Gray Iron
Design No. 60
Spool Center Condition A Port and Double Offset sensing switch on B Port
Pilot Valve Type N/A
Solenoid Indicator Lights Code L
Function 3-Position Detented
Response Time 15 to 23 ms
Port Restrictor Plugs None
Electrical Options None
Operation Solenoid Operated
Port T Pressure Rating 3000 psi
Spool Indicator Switch Code None
Pilot/Drain None
Actuator Type Solenoid
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison