- D03 Pressure Reducing Valve
- Pilot Control is on Pressure Port
- Pressure Adjustment Range is 290-3,625 psi
- Screw w/Locknut Adjustment on Port B End
- SAE-4 Gage Port
description
- Single-stage valves operate by the application of pressure on the end of the valve spool, acting against a spring which is loaded by means of the manual adjustment mechanism.
- Flow path is normally-open and is closed as the pilot pressure exceeds the manual setting of the valve. Excessive pressure in the reduced pressure line is prevented by a pressure relieving function.
Family Name | Vickers D03 SystemStak™ Valves |
Model No. | DGMX2-3-PP-FW-S-40 |
External Drain | No |
Pilot Control | Pressure Port |
Remote Control Port | No |
Operating Pressure [Max] | 4500 psi |
Port Control | Pressure Port |
Flow [Max] | 16 gal/min |
Adjustment Type | Screw w/ Locknut |
Adjuster Location | Port B End |
Valve Type | Pressure Reducing Valve "P" Port |
Manufacturer Part No. | DGMX2-3-PP-FW-S-40 |
Pressure Adjustment Range (psi) | 290 to 3,625 |
Gage Port | SAE-4 |
Design No. | 40 |
Interface | D03 |
Weight | 2.6 LB |